Henan Sanqiang Medical Equipment Liability Co.,Ltd

Medical Sterilizer manufacturers / suppliers, offering Medical Sterilizer, Plasma Sterilizer, Ethylene Oxide Sterilizer, EO Gas Sterilizer, Steam Sterilizer , Low Toxic Sterilizer and so on.

About Us

  • 1
  • 2
  • 3
  • 4
Henan Sanqiang Medical Equipment Liability Co.,LtdHenan Sanqiang Medical Equipment Liability Co.,LtdHenan Sanqiang Medical Equipment Liability Co.,LtdHenan Sanqiang Medical Equipment Liability Co.,Ltd
Henan Sanqiang Medical Equipment Liability Co.,Ltd
Address: Middle Section of Xihuan Road, Hexi Industrial Area, Daokou Town, Huaxian County, Anyang, Henan, China
Member Since: 2018
Main Markets: Africa , Asia , Middle East

Contact Us

Mobile:
Tel:
Fax:

Mr. Jay Wong

Contact Us
Recommended Products
New Products
Plasma sterilizer sales price

Product Description: Plasma sterilizer sales price Plasma sterilizer sterilizable items and materials Metal instruments, hysteroscopes, laparoscopes, laryngoscopes, probes, rigid endoscopes, hose endoscopes, ophthalmic lenses, fiber optic cables, intracranial sensors, cryotherapy probes, resectoscopes, esophageal dilators, electrocautery Equipment, defibrillation motors, laser heads, metals, glass, silicones, rubbers, etc. 1, environmental protection and safety: Hydrogen peroxide solution as a medium, the specific electromagnetic field excitation to form a plasma and complete sterilization, the final product is a small amount of water vapor and oxygen, non-toxic residue and discharge, no harm to medical staff, no pollution to the environment 2, low temperature: sterilization temperature is about 50 °C, no damage to equipment and goods, can extend the life of expensive medical devices 3, fast and efficient: short sterilization cycle, fast mode and standard mode, no need to adopt other enhancement methods for complex lumen equipment. After the sterilization is completed, the device can be used directly, greatly improving the turnover rate of the device, reducing the loss and spare capacity of expensive devices. 4. Plasma sterilizer sterilization cabin: A square sterilizing chamber has high plasma uniformity and no sterilization blind area. The large effective sterilization volume reduces the overall sterilization cost; the depth of the sterilization chamber can reach 810mm, even if it is a long device. 5, open the door: unique foot switch, chic mechanical lift door, intimate anti-pinch hand function 6.Plasma sterilizer simple operation and monitoring: no need of high temperature, high pressure, safe use; touch screen design, clear and intuitive, easy to operate; automatic monitoring system will automatically monitor the system operating parameters during the startup and sterilization process of the equipment, abnormalities will automatically terminate Sterilization process, alarms and indications of failures to ensure healthy operation of equipment. Automatically record all operating parameters during the operation process and can automatically print sterilizing conditions through the micro-printer to improve the level of hospital management 7. Installation requirements: no special drainage, ventilation, detoxification facilities, free movement

Ethylene oxide sterilizer sales

Product Description: Ethylene oxide sterilizer sales SQ-H series Ethylene oxide sterilizer produced by the Sanqiang company uses a mixture of pure ethylene oxide and ethylene oxide gas at a certain temperature,pressure,humidity and a certain working time,and it is sealed and sterilized.Indoor equipment for low-temperature fumigation sterilization equipment.Ethylene oxide gas is a very active chemical disinfectant that not only achieves broad-spectrum sterilization,but also achieves reliable sterilization. thylene oxide sterilizer sterilization method: The Ethylene Oxide Sterilizer is a very specific alkylation reaction between ethylene oxide and microorganisms,which inhibits the normal reaction of microbial reaction groups and causes their metabolic metabolism to die.The sterilization process is in full charge.Bacteria gas is carried in the high pressure chamber. Ethylene oxide sterilizer product structure: Ethylene oxide sterilizer product consists of an electric control box,a sterilization chamber,a system control box,a sensing system box and an exhaust gas treatment system. Electric control box:The shell is made of 304 steel plates with a motherboard inside. Sterilization room:Made of high quality 304 stainless steel plate. System control box:It is composed of vacuum pumping system,drainage system,heating system,purification system,water circulation system and air filtration system. Specifications and models: SQ-H-120(1000L),SQ-H220(2000L),SQ-H360(3000L),SQ-H460(4000L),SQ-H600(6000L),SQ-H800(8000L),etc. Ethylene oxide sterilizer scope of application Medical category: 1.Endoscope(such as laryngoscope,bronchoscope,cystoscope,urethroscope,mediastinoscopy,thoracoscope,esophageal fiberscope) 2,equipment and equipment(such as surgical suture,suture,suture needle,artificial esophagus,artificial bone,artificial blood vessels,etc.) 3,anesthesia vessels(such as organ hose,nasal hose,tracheostomy application catheter,suction hose closed road,etc.) 4.Plastics and rubber products(such as gloves,fingertips,syringes,injection needles,blood collection devices,infusion devices,urine collection bags,etc.) 5.Cotton fiber products and others(such as clothes,gauze,bandages,cotton balls,cotton swabs,absorbent cotton,towels, blankets,etc.) Instrumentation:electronic instruments,optical instruments,telephones,etc. Other:People's City,Tickets,Medical Records,Archives,Letters,Historical Relics,Satin Products,Animal Specimens,etc. Features 1,computer control,liquid crystal display,ethylene oxide sterilizer using liquid crystal display,simple operation,clear,intuitive temperature,pressure,temperature,sterilization time,residual gas processing, extinction analysis,and other work processes 2,fault alarm system, ethylene oxide sterilizer high temperature alarm,overpressure alarm,ultra-low alarm,leak alarm. 3,double protection doors,double protection doors with insulation,sealing,lock code and other functions,easy to use,to ensure no leakage of ethylene oxide gas. 4.During the sterilization process,the sterilizer is under negative pressure,so ethylene oxide gas will not leak. 5,automatic humidification system Ethylene oxide sterilizer can add the relative temperature of the sterilization chamber to 60% to 80%. 6.Automatic memory function,accidental relaying during system operation,after restart,the system automatically saves the original parameters before relay and continues to run. 7,automatic printing function,ethylene oxide sterilizer has a Chinese character print function,and record all the work process,ready for preservation. 8.The residual gas is harmlessly treated. The ethylene oxide sterilizer uses chemical methods to treat the residual gas.It is safe to use and does not pollute the environment. 9,heating is the use of water circulation technology to warm up,product energy is not over temperature 10,the product has an automatic parsing function,after the parsed item is to be used for clinical

Vertical ethylene oxide sterilizer

Product Description: Vertical ethylene oxide sterilizer Vertical ethylene oxide sterilizer operation flow First,put a small gas tank into the hole, and then put the sterilized items; Second,turn on the ethylene oxide sterilizer power; Third, check the relevant pipeline is normal,whether the water source is open; Fourth,put the items to be eliminated and close the sterilizer door; 5Turn the power switch to display the initial state.After stopping for 5 seconds,press the Start key.The digital screen displays the sterilization-related parameters.Then press the Start key again and the device will automatically run. 6.Display END.After sterilization is completed,remove the sterilized items and close the door. 7.Sterilization:It should be performed in accordance with the operating instructions of the manufacturer of Vertical ethylene oxide sterilizer;according to the types of sterilization items,packaging, loading and methods,choose the appropriate sterilization parameters. 1,the relationship between concentration,temperature and sterilization time: Within a certain range,the temperature increases,the concentration increases,can shorten the sterilization time.The temperature,concentration and time parameters must be properly selected when using ethylene oxide sterilization. 2.Control the Relative Humidity of the Sterilization Environment and the Water Content of the Articles:The water content of the bacteria and the water content of the sterilization articles have a significant effect on the sterilization effect of ethylene oxide.In general,the relative humidity is preferably 60% to 80%.Too little water content affects the penetration of ethylene oxide and the alkylation of ethylene oxide,reducing its bactericidal capacity;too much water, ethylene oxide is diluted and hydrolyzed,but also affect the sterilization effect.In order to achieve the ideal humidity level, the first step is that the sterilized material must be pre-wet.Generally,it is required that the sterilized material be placed in an environment of 50% relative humidity for at least 2 hours;in the second step, the humidifier can be used to ensure the ideal humidity in the cabinet.Level. 3.Note the effect of extracellular substances on sterilization:The more organic matter on the surface of bacteria,the more difficult it is to kill;organic matter can not only affect the penetration of ethylene oxide,but also can consume part of the ethylene oxide.Microorganisms in inorganic salts or organic crystals are difficult to kill with ethylene oxide.Therefore, before the ethylene oxide sterilization,the organic and inorganic dirt on the article must be fully cleaned to ensure the sterilization is successful.

Medical ethylene oxide sterilizers

Product Description: Medical ethylene oxide sterilizers Ethylene oxide sterilizer is through its non-specific alkylation with microorganisms,thereby inhibiting the normal function of the microbial reaction base,causing its metabolism to die and die.Medical ethylene oxide is related to the temperature,pressure,humidity,and concentration of ethylene oxide in the sterilization chamber.These process parameters can shorten the sterilization time and achieve the best sterilization effect with appropriate values.Therefore,the working process of the Medical ethylene oxide first warms the sterilization chamber until the temperature reaches a predetermined sterilization temperature;then,the sterilization chamber is evacuated,and when the predetermined degree of vacuum is reached,the sterilization chamber is started to be filled;After the above process is finished, the fixed clock starts to work and the sterilization process starts;during the entire sterilization process,the temperature needs to be maintained;when the sterilization time arrives, the sterilization chamber starts to be ventilated,ie,the filtered clean air is used.Displace the residual ethylene oxide gas in the sterilization chamber and discharge the residual gas;the residual gas is discharged after being processed by the exhaust gas treatment system.At this point,the entire sterilization process is over. Medical ethylene oxide consists of an electric control box,a sterilization chamber,a system control box,a sensing system box and an exhaust gas treatment system. Electric control box:The shell is made of 304 steel plates with a motherboard inside. Sterilization room:Made of high quality 304 stainless steel plate. System control box:It is composed of vacuum pumping system,drainage system,heating system,purification system,water circulation system and air filtration system. Specifications and models: SQ-H120(1000L),SQ-H220(2000L),SQ-H360(3000L),SQ-H460(4000L),SQ-H600(6000L),SQ-H800(8000L),etc. Advantage: 1,a key operation,microcomputer control,simple and convenient,digital display sterilization process. 2.Sterilize the information recorded in the sterilization process for easy verification and archiving. 3,the air inlet is equipped with a filter system,which can effectively filter bacteria and microorganisms and avoid secondary pollution when discharged.

EO gas sterilizer sales

Product Description: EO gas sterilizer Sales Ethylene oxide sterilizer series EO gas sterilizer produced by the Sanqiang company has beautiful appearance, reliable quality,simple operation,safe use and reasonable price.EO gas sterilizer is a kind of advanced sterilization equipment.Under certain conditions,ethylene oxide gas is used to sterilize the articles sealed in the sterilization chamber at low temperature;Ethylene oxide can kill.Various types of microorganisms,including bacteria,Mycobacterium tuberculosis,fungi,Bacillus and viruses.It has strong penetrating power and can penetrate microporous cotton fabrics,plastic films,carton boxes and other packaging items.Sterilization is reliable and easy for long-term storage.The sterilized items are placed in a well-ventilated room and can be safely used after volatilization. EO gas sterilizer main structure configuration: 1,heating cycle device 2.Humidifier 3,gasification device 4.Pneumatic device 5,vacuum system 6,air filter 7,residual gas treatment device 8,electronic control system 9,inside and outside the loading transport equipment

Microcomputer control sterilizer sales

Product Description: Microcomputer control sterilizer sales Ethylene oxide sterilizer is the latest computer Microcomputer control sterilizer developed and produced by our company.Its technical level and manufacturing process are in the leading position in China.Microcomputer control sterilizer product is controlled by microcomputer and vacuum sterilization room.System,constant temperature system,residual gas treatment system.When you use it,you only need to press the Run button twice to realize complex processes such as automatic heating,vacuum,vaporization,sterilization,and evacuation,which is very convenient and safe.Sterilization is almost 100%.At the same time,the ethylene oxide gas used in this equipment has flame-retardant,explosion proof,penetrating power,efficient broad-spectrum sterilization,short sterilization time,no corrosion,no residue,no Environmental pollution and other characteristics.This product has unique advantages for sterilizing and sterilizing items that are afraid of humidity and heat.At present,it is widely used in the fields of medical and health,industry,foreign trade,commerce,banking,archeology,archaeological archives management and cultural relics management. Microcomputer control sterilizer operation flow First,put a small gas tank into the hole,and then put the sterilized items; Second,turn on the power; Third, check the relevant pipeline is normal,whether the water source is open; Fourth,put the items to be eliminated and close the sterilizer door; 5.Turn the power switch to display the initial state.After stopping for 5 seconds, press the Start key.The digital screen displays the sterilization-related parameters.Then press the Start key again and the device will automatically run. 6.Display END. After sterilization is completed, remove the sterilized items and close the door. The operator should carefully read the instruction manual and master the method before operating.Before power on,it must check whether the overflow has been added to the overflow port.The operation must be performed in the order listed in Using and operating methods.If you accidentally touch the keyboard during operation,you need to turn off the power switch and restart the power supply to operate. When the power is turned off and then on again, it needs to be separated by more than ten seconds. Otherwise,the display part may be confused and the ethylene oxide vial gas storage place should be empty.Fire source, no heat source, no sun,good ventilation,temperature less than 30°C,but can not put in the refrigerator.If the cylinder temperature is lower than zero,it should be allowed to reach room temperature before it can be used. The product is provided with packing list,certificate,warranty card,and ethylene oxide sterilization box after packaging.It should be stored at a relative humidity of no more than 80%.Non-corrosive gases and well-ventilated rooms are strictly prohibited to be disassembled and twisted. When transporting,they should be lightly loaded,not tilted,squared or inverted.

Gas sterilizer sales price

Product Description: Gas sterilizer sales price Henan Sanqiang Medical Devices Co.,Ltd.has taken the lead in starting medical equipment companies in Hua County,Henan Province in 2000. Gas sterilizer After years of development,the company now covers an area of over 54,000 square meters.With our professionalism and mature technology in the field of medical equipment,we have rapidly emerged in the medical field and are committed to research and innovation,based on the introduction of advanced German technology.Has successfully developed a series of low temperature plasma hydrogen peroxide sterilizers,Ethylene oxide sterilizer,dry heat sterilizers, hot and humid fast high pressure steam sterilizers,three pre-vacuum pulsed steam autoclaves,Speculative storage cabinets,ultrasonic cleaning machines and related consumables;Ethylene oxide is the second-generation chemical disinfectant following formaldehyde,and it is still one of the best cold disinfectants and is currently the four major cryogenic sterilization technologies.(Low temperature plasma,low temperature formaldehyde vapor,ethylene oxide,glutaraldehyde)is the most important member.EO is a simple epoxy compound.It is a non-specific alkyl compound and its molecular formula is C2H4O. Therefore,ethylene oxide sterilizer is a more traditional sterilization method. 1)There are many kinds of ethylene oxide sterilizers currently in use.Large-scale vessels have dozens of cubic meters,medium ones have 1 to 10 cubic meters, and small ones have zero to one cubic meter.They have different uses. Large-scale ethylene oxide sterilizer:It is generally used for the sterilization of a large number of articles.The dosage is 0.8kg/m to 1.2kg/m,and the action is 55°C~60°C for 6 hours. 3)Medium-sized ethylene oxide sterilizer:generally used for sterilization of disposable medical supplies.This kind of sterilization equipment is perfect,with a high degree of automation. Pure ethylene oxide or mixed gas of ethylene oxide and carbon dioxide can be used.General requirements for sterilization are:concentration,800 mg/L~1000 mg/L,temperature, 55°C~60°C,relative humidity 60%~80%,duration of action 6 h.Vacuum is required for sterilization.Sterilized articles are usually sealed tightly through ethylene oxide-based plastic film.If you have a filter that filters air on a small package, sterilization is better. 4)Smaller ethylene oxide sterilizers are used in medical and health departments to handle a small number of medical devices and supplies.There are currently 100% pure ethylene oxide or mixed gas of ethylene oxide and carbon dioxide.Such sterilizers have a relatively high degree of automation,can automatically vacuum,automatically add drugs,automatically adjust the temperature and relative humidity,can automatically control the sterilization time. 5)The requirements for medium and small-sized ethylene oxide sterilizers are as follows: good pressure resistance and airtight performance,water pressure test that can withstand 1.25 times the working pressure,no denaturation and leakage,and vacuum degree More than 60 kPa;accurate dosing,good insulation performance,can adjust the temperature and relative humidity within the sterilizer;when sterilized with external air,the input air passes through a high efficiency filter,which can filter out 99.6 particles of≥0.3μm% or more;the discharged residual ethylene oxide is harmlessly treated,and the residual ethylene oxide in the sterilization article should be less than 15.2 mg/m;the concentration of ethylene oxide in the sterilization environment should be less than 2 mg/m.

Instrument plasma sterilizer sales

Product Description: Instrument plasma sterilizer sales Instrument plasma sterilizers is a new cryogenic sterilization technology that began in the 1990s.Plasma is considered to be the fourth state outside the liquid, gas,and solid states.It is formed when gas molecules are excited in an extremely vacuum chamber.Hydrogen peroxide plasma sterilization has the advantages of short sterilization cycle time and complete decomposition of the low toxicity of the final product. Instrument plasma sterilizers can perform both low temperature sterilization of metal medical devices and low temperature sterilization of non-metallic medical devices.The medical device is sterilized by diffusion of hydrogen peroxide in the chamber and then inspire hydrogen peroxide into a plasma state.Hydrogen peroxide vapor combines with plasma to safely and quickly sterilize medical devices and materials without leaving any toxic residues.All phases of the sterilization process are run in a dry,low-temperature environment,so that instruments that are sensitive to heat or moisture are not damaged.They are suitable for both metal and non-metallic devices and can be difficult to reach for such things as hemostatic clamp hinges.The parts of the instrument are sterilized. advantage: Rapid bactericidal action,easy decomposition of H2O2,no exhaust time,fast turnover of items, no installation requirements,no ventilation ducts Disadvantages Poor penetration,a device has a strict lumen length,the lumen size of the sterilization mechanism,for the oxidation reaction,the material of the device is strictly limited,when the sterilization device is absolutely dry, can not be oiled. Plasma sterilized items cannot be used: Incompletely dried articles,single use articles,articles or materials that attract liquids,an enclosed cavity,liquids or powders,instruments that cannot withstand vacuum,instruments that are labeled for use only by pressure steam sterilization, and instruments that have internal components,Difficult to clean items made of cellulose-containing materials or any other items and implants containing wood pulp. Plasma sterilizer Consumables: Hydrogen peroxide solution,chemical indicator card,biological indicator,special packaging bag or non-woven fabric. .

Automatic door plasma sterilizer

Product Description: Automatic door plasma sterilizer Medical supplies sterilizer features:Medical supplies sterilizer device comes with a biological indicator incubator:a special constant-temperature 6-well incubator controlled by Micro-German Siemens PLC, which is used for constant temperature culture of biological indicators for monitoring the sterilization effect.≤±0.3 in the full range°C temperature control accuracy;temperature can be set up by itself, this design was pioneered in China,to achieve a dual-purpose machine,saving procurement costs and space utilization. Plasma sterilizer hydrogen peroxide sterilization self-contained biological indicators,with Bacillus stearothermophilus(ATCC7953)as an indicator bacteria.It consists of bacteria,medium(sealed in a glass tube)and a plastic shell.Strain spore content≥1.0×106 cfu.At a temperature of 50°C±0.5°C,a relative humidity of 60%±10% RH,and a sterilization condition of 2.3 mg/l±0.4 mg/l H2O2, the D value was 0.75 to 8 seconds. Use range: Suitable for monitoring the sterilization effect of low temperature plasma hydrogen peroxide sterilizer. Instructions: Put this product into a special plasma packaging bag; Determine the most difficult sterilization point in the sterilizer(usually at the lower end of the sterilizing chamber)and place the packaging bag containing the product in the sterilizer; After sterilization, the tube was removed and allowed to cool at room temperature. After cooling,the plastic tube of the indicator was squeezed with a plastic clamp to crush the glass tube in the plastic tube,confirming that the bacteria pieces were completely immersed in the culture solution, and pressing the top cover to seal the plastic tube and the top of the cover. 4.Please raise the test tube upright at a temperature of 56°C~60°C.For the sake of comparison,please use the same batch of non-sterile indicator and treat it as before,and culture together as a positive control tube. 5.After 48 hours of culture,if the culture solution is still purple for sterilizing,if the discoloration is incomplete,it will be positive.If it is still purple,it means that sterilization is complete and it is negative. Precautions: Biomonitoring results are valid only when the positive control tube is positive(purple turns yellow). Before use,please confirm the integrity of the product,the lid side hole is not closed and allowed to return to room temperature. 3,please save the temperature 4~25°C,relative humidity 30~70% conditions, away from the sterilizer,avoid sunlight or ultraviolet radiation,do not freeze! 4,please use within the validity period,valid for one year from the date of production. 5,positive biological indicators please dispose after sterilization

Automatic plasma sterilizer sales

Product Description: Automatic plasma sterilizer sales Automatic plasma sterilizer sterilizable items and materials: Metal instruments, hysteroscopes,laparoscopes,laryngoscopes,probes,rigid endoscopes,hose endoscopes,ophthalmic lenses,fiber optic cables,intracranial sensors,cryotherapy probes,resectoscopes, esophageal dilators,electrocautery Equipment,defibrillation motors,laser heads,metals,glass,silicones,rubbers.etc. Non-sterile items and materials: Incompletely dried articles,single use articles,articles or materials that attract liquids,an enclosed cavity,liquids or powders,instruments that cannot withstand vacuum,instruments that are labeled for use only by pressure steam sterilization,and instruments that have internal components,Difficult to clean items made of cellulose-containing materials or any other items and implants containing wood pulp. Consumables:plasma biological indicator,hydrogen peroxide sterilizer,chemical indicator(card),non-woven fabrics,special packaging bags. In general,whether the plasma sterilizer can be sterilized can be seen from the success of the chemical indicator card, such as: The plasma sterilization indicator card is composed of special cardboard,standard color blocks,and indicator color blocks.It is made of thermal chemical substances and color developing agents and auxiliary materials.The ink is printed on the printed standard color blocks(beige On a special card,or yellow),the indicated color block(grass green)is displayed.Hydrogen peroxide is applied to reach the required temperature in the sterilizer,and it acts for a specified time to indicate that the color block changes from grass green to yellow or yellow,indicating sterilization. Automatic plasma sterilizer applicable to low-temperature plasma sterilizer,used to indicate whether the package has been plasma sterilized;take the indicator card between the devices to be sterilized, wrapped with gauze,and then placed at 45°C~55°C low temperature plasma After 25 minutes in the sterilizer,the indicated color marker of the indicator card changed from grass green to beige or yellow,and it was determined that the sterilization packet had been plasma-sterilized.Sterilization and records can be written directly on the surface of the indicator card

Medical plasma sterilizer sales

Product Description: Medical plasma sterilizer Medical plasma sterilizer technical advantages 1,Medical plasma sterilizer: sterilization temperature of 50°C± 5°C,low temperature and no humidity,no damage to the sterilization articles and equipment,can extend the life of precision instruments. 2.Medical plasma sterilizer green and environmental protection:hydrogen peroxide solution is used as sterilizing agent,no toxic substance remains,no drainage or exhaust is required,no damage to the operator's body,and special filters for high efficiency can be applied to the air intake and exhaust ports.Absorption of H2O2 from the process of vacuum rejection will result in zero pollution to the environment. 3.Medical plasma sterilizer sterilization stability:The sterilization chamber is made of aluminum or stainless steel,which has advantages of anti-corrosion and thermal conductivity,which makes the temperature of the sterilization chamber more balanced and effective, and ensures that H2O2 maintains 100% of the gas throughout the process.The hydrogen peroxide low temperature storage system ensures that the hydrogen peroxide concentration is stable and effective and does not volatilize. 4.High sterilizing efficiency:The design of a rectangular sterilization chamber makes it possible to load more instruments at a time and make the use of the sterilization chamber more convenient. 5.Safety and stability of the sealed door:It adopts a top pole-driven electric lift door,which runs smoothly and has a safety interlock device to avoid safety hazards caused by misoperation of equipment and operators. 6,easy installation and operation:the use of high intelligent control processor,a key to start,easy operation, power can be used. 7.Configuration:The compatibility of the selected configuration is smooth.Control systems,vacuum pumps,pressure sensors,gauges,solenoid valves and other key hardware are imported components. Diversified program selection,control system can be upgraded and maintained. 8,save time and money:The sterilization cycle is short,within 45 minutes to complete the sterilization,direct use,without any treatment,each sterilization costs low,can increase the turnover rate of sterilized instruments,reduce costs. 9.The air inlet is equipped with a sterile filter:it can effectively filter germs and microorganisms and avoid secondary pollution when discharged. 10,U disk storage function:disk capacity≥8G,able to store records≥1 million sterilization data,storage information including program serial number,sterilization date,sterilization pot times,sterilization start and end time and sterilization process pressure,temperature,phase time, and end status,and provide computer-based print samples. 11.Biological Indicator Incubator:It adopts a micro-computer-controlled constant temperature incubator for biological indicators,which is used for the constant temperature culture process of the biological indicator for monitoring the sterilization effect,and the temperature accuracy is ≤±0.3°C within the full range. Settings. 12.Properties of Hydrogen Peroxide Solution:The sterilizing agent used in this device is a 60% hydrogen peroxide solution that can inactivate resistant bacterial spores.Hydrogen peroxide is a colorless liquid with strong oxidizing properties and its aqueous solution is weakly acidic.Hydrogen peroxide solution is an explosive strong oxidant.Hydrogen peroxide is not flammable on its own,but it reacts with flammables to release a large amount of heat and cause a fire explosion. 13,bottled hydrogen peroxide storage:Bottled hydrogen peroxide should be stored in a well-ventilated,dry and cool,the temperature is lower than 25°C environment.Keep away from combustibles, heavy metals,catalytic metal compounds,heat sources,and ignition sources when storing.Please use it within the valid period of the product to avoid unqualified sterilization

Environmental protection type sterilizer

Product Description: Environmental protection type sterilizer Environmental protection type sterilizers,Plasma sterilizer dry sterilization at room temperature and is the result of a combination of various sterilization conditions: 1, the role of active genes: the plasma contains a large number of active oxygen ions, high-energy free groups and other components, easily with bacteria, mold, spores and virus proteins and nucleic acid substances in the oxidation reaction and denaturation, so that the death of various microorganisms . 2, high-speed particle breakdown: After sterilization experiments by electron microscopy, the effect of the plasma after the bacteria and virus particles, showing a hundred holes, which is generated by the high kinetic energy of electrons and ions Etch and breakdown effects. 3, the role of ultraviolet light: In the process of exciting H2O2 to form a plasma, along with some of the UV light generated, this high-energy UV photon (3.3-3.6EV) is absorbed by microorganisms or proteins in the virus, resulting in degeneration of its molecular degeneration. Sterilization range Metal materials: Most metals such as stainless steel, aluminum, copper, and titanium. Non-metallic materials: Glass, Polyethylene, Latex, Polycarbonate, Poly Bing, Silicone, Teflon, Chloropropene, Polystyrene, Polyvinyl chloride, etc. Equipment categories: soft and hard endoscopes, endoscopic equipment, laser heads, esophageal dilators, cold probes, power equipment and batteries, razor heads, ultrasound probes, fiber optics and pacing lead wires, fiber optic cables, Electronic equipment and wires, metal equipment, glassware. Sterilization is not suitable for sterilization: diameter less than 1mm, length greater than 500mm stainless steel tubular instruments hygroscopic material (disposable waterproof fabrics, disposable surgical clothing, etc.) liquid or powder is not completely dry items, one end of the occlusion cavity, generally Implants. SQ-D-100 low temperature plasma sterilizer technical parameters. Design pressure: ultimate vacuum Dimensions: 1070mm*800mm*1710mm(L*W*H) Effective volume: 100L Working temperature: 3°C-55°C Power supply: AC220V/50Hz/3.9Kw Working mode: fast mode, enhanced mode Vacuum pressure value: ≤60Pa Plasma pressure value: ≤60Pa Working noise: <65db Ambient temperature: 5°C-40°C Humidity: <80% Environmental pressure: 86KPA-106KPA Hydrogen peroxide: (H2O2) concentration 60% Return air filter: 0.2um99.99% filtration rate

Hydrogen peroxide sterilizer sales

Product Description: Hydrogen peroxide sterilizer sales Hydrogen peroxide sterilizer can perform both plasma sterilizer,of metal medical devices and low temperature sterilization of non-metallic medical devices.The medical device is sterilized by diffusion of hydrogen peroxide in the chamber and then inspire hydrogen peroxide into a plasma state.Hydrogen peroxide vapor combines with plasma to safely and quickly sterilize medical devices and materials without leaving any toxic residues. All phases of the sterilization process are run in a dry,low-temperature environment,so that instruments that are sensitive to heat or moisture are not damaged. They are suitable for both metal and non-metallic devices and can be difficult to reach for such things as hemostatic clamp hinges.The parts of the instrument are sterilized. 1.Properties of Hydrogen Peroxide Solution:The sterilizing agent used in this device is a 60% hydrogen peroxide solution that can inactivate resistant bacterial spores.Hydrogen peroxide is a colorless liquid with strong oxidizing properties and its aqueous solution is weakly acidic.Hydrogen peroxide solution is an explosive strong oxidant.Hydrogen peroxide is not flammable on its own,but it reacts with flammables to release a large amount of heat and cause a fire explosion. 2.Storage of Bottled Hydrogen Peroxide:Bottled hydrogen peroxide should be stored in a well-ventilated,cool, dry place with temperatures below 25°C.Keep away from combustibles,heavy metals,catalytic metal compounds,heat sources,and ignition sources when storing.Please use it within the valid period of the product to avoid unqualified sterilization. 3.Emergency treatment:Hydrogen peroxide is oxidizing and easily permeates the skin,causing temporary damage to the skin.Always wear latex or vinyl gloves when handling the solution and handle empty bottles properly.If you accidentally come in contact with the skin,rinse the affected area thoroughly with plenty of water for about 5 minutes or more.If you inhale or swallow the sterilant, drink plenty of water immediately and seek medical attention. Hydrogen peroxide sterilizer CAUTION If the program is interrupted or the operation is cancelled due to an abnormality in the operation,please handle it with latex or vinyl gloves and be careful not to let the gloves come in contact with your face or eyes.At this point,there may be residual hydrogen peroxide inside or on the surface of the incompletely sterilized article.

Low temperature plasma sterilizer

Product Description: Low temperature plasma sterilizer Low temperature plasma sterilizers can perform both low temperature sterilization of metal medical devices and low temperature sterilization of non-metallic medical devices. The medical device is sterilized by diffusion of hydrogen peroxide in the chamber and then "inspire" hydrogen peroxide into a plasma state. Hydrogen peroxide vapor combines with plasma to safely and quickly sterilize medical devices and materials without leaving any toxic residues. All phases of the sterilization process are run in a dry, low-temperature environment, so that instruments that are sensitive to heat or moisture are not damaged. Low temperature plasma sterilizers are suitable for both metal and non-metallic devices and can be difficult to reach for such things as hemostatic clamp hinges. The parts of the instrument are sterilized. 1Open the door: unique foot switch, chic mechanical lift door, intimate anti-pinch function 2 The operation and monitoring are simple: no high temperature, high pressure, and safety are required; the touch screen design is clear, intuitive and easy to operate; the automatic monitoring system will automatically monitor the system operating parameters during the startup and sterilization of the equipment, and the abnormality will be automatically terminated. Bacteria process, alarm and indicate the point of failure to ensure the healthy operation of equipment. Automatically record all operating parameters during the operation process and can automatically print sterilizing conditions through the micro-printer to improve the level of hospital management 3 installation requirements: no special drainage, ventilation, detoxification facilities, free movement The plasma indicator card is used to make ink from the heat-sensitive chemical substance, color developing agent and auxiliary materials. The ink is printed on a special card printed with a standard color block (beige or yellow). The display color block (grass green) is displayed. . Hydrogen peroxide is applied to reach the required temperature in the sterilizer, and it acts for a specified time to indicate that the color block changes from grass green to yellow or yellow, indicating sterilization. Suitable for use in low temperature plasma sterilizers to indicate whether the package has been plasma sterilized. Take the indicator card between the device to be sterilized, wrapped with gauze, and then placed in a 45 °C ~ 55 °C low temperature plasma sterilizer for 25 minutes, indicating the color of the indicator mark changes from grass green to beige Or yellow, it can be determined that the sterilization package has been plasma sterilized. Sterilization and records can be written directly on the surface of the indicator card Low temperature plasma sterilization process instructions. Quickly and intuitively reflects whether the sterilized items are sterilized. After use, it can be used as a sterilization record for preservation. Instructions: 1. Place the indicator card with the sterilized object in the packaging bag. 2, try to avoid full coverage of the instrument on the card. 3. Observe the indicator card after the sterilization. Red turns yellow to indicate that the sterilization is acceptable. Precautions: Keep away from acids, alkalis, and oxidizing materials. 2. Store in dark and cool place (below 25°C). 3, remove the required number of roots and tighten the lid

Medical sterilizer sales price

Product Description: Medical sterilizer sales price Plasma medical sterilizer can perform both low temperature sterilization,Plasma sterilizer of metal medical devices and Medical sterilizer,Medical sterilizer of non-metallic medical devices.Medical sterilizer is sterilized by diffusion of hydrogen peroxide in the chamber and then"inspire"hydrogen peroxide into a plasma state.Plasma sterilizerhydrogen peroxide vapor combines with plasma to safely and quickly sterilize medical devices and materials without leaving any toxic residues.all phases of the sterilization process are run in a dry,low-temperature environment,so that instruments that are sensitive to heat or moisture are not damaged.Medical Sterilizer are suitable for both metal and non-metallic devices and can be difficult to reach for such things as hemostatic clamp hinges. The parts of the instrument are sterilized. 1.Medical sterilizer articles and materials that can be sterilized:metal instruments,hysteroscopes,laparoscopes,laryngoscopes,probes,rigid endoscopes,hose endoscopes,ophthalmic lenses,fiber optic cables,intracranial sensors,cold probes,Prostate resectors,esophageal dilators,electrocautery devices,defibrillation motors,laser heads,metals,glass,silicones,and rubbers. 2.Medical sterilizer articles and materials that cannot be sterilized:incompletely dried articles,disposable articles,liquid-attracting articles or materials,an enclosed cavity,liquid or powder,instruments that cannot withstand vacuum,and the use of pressure only Steam-sterilized instruments and instruments have internal parts,articles that are difficult to clean,made of cellulose-containing materials,or any other articles and implants that contain wood pulp. 3,Medical sterilizer consumables:plasma biological indicator,hydrogen peroxide sterilizer,chemical indicator(card),non-woven fabrics,special packaging bags. 1)Hydrogen peroxide solution Properties:The sterilizing agent used in this device is a 60% hydrogen peroxide solution that can inactivate resistant bacterial spores.Hydrogen peroxide is a colorless liquid with strong oxidizing properties and its aqueous solution is weakly acidic.Hydrogen peroxide solution is an explosive strong oxidant 2)Low-temperature plasma hydrogen peroxide sterilize self-contained biological indicators for detecting the sterilization effect,using Bacillus stearothermophilus(ATCC7953)as an indicator. It consists of bacteria,medium(sealed in a glass tube)and a plastic shell.Strain spore content≥1.0×106 cfu.At a temperature of 50°C±0.5°C,a relative humidity of 60%±10% RH,and a sterilization condition of 2.3 mg/l±0.4 mg/l H2O2,the D value was 0.75 to 8 seconds. 3)The plasma sterilization indicator card is made of thermal sensitive chemical substances,color developing agents and auxiliary materials.The ink is printed on a special card printed with a standard color block(beige or yellow),indicating color blocks(Grass green).Hydrogen peroxide is applied to reach the required temperature in the sterilizer,and it acts for a specified time to indicate that the color block changes from grass green to yellow or yellow,indicating sterilization. 4)Nonwovens,also known as nonwovens,consist of oriented or random fibers.Because of its cloth's appearance and certain properties,it is called cloth,which is mainly used for packaging instruments that need to be sterilized. 5)One sided paper(DuPont Tyvek Tyvek Paper/French medical dialysis paper/British medical blister paper)+one side of the composite plastic film,the medical device is put into the packaging bag(product),and then sealed and sterilized.

Plasma Sterilizer
Ultrasonic Cleaning Machine
Indication Label

News

Wet heat steam sterilizer supplier

Wet heat steam sterilizer is sterilized by hot steam.At the same temperature,the reason why the heat of dampness is better than that of dry heat is 1,Hot steam has a more damaging effect on cellular components.The presence of water molecules helps to destroy hydrogen bonds and other interacting weak bonds that maintain the three dimensional structure of the protein,making it easier to denature proteins.The water content of protein is inversely proportional to its solidification temperature. 2,Hot steam is more penetrating than hot air,which can kill microorganisms more effectively. 3.The steam has latent heat.When the gas is converted into a liquid,a large amount of heat can be released,so that the temperature of the sterilized object can be quickly increased. Most vegetative cells of bacteria and fungi can be killed after treatment at 60 °C for 15 min.The cells of yeast and fungi should be heat resistant.It must be treated with a temperature above 80 °C to kill,and the spores of bacteria are more resistant to heat.It usually takes 15 minutes to kill at 120 °C. Common methods for wet heat steam sterilizers are atmospheric steam sterilizers and high pressure steam sterilizers. Henan Sanqiang Medical Equipment Liability Co.,Ltd has successfully developed low temperature plasma hydrogen peroxide sterilizer,ethylene oxide sterilizer,dry heat fast sterilizer,moist heat fast sterilizer,Wet heat steam sterilizer,endoscope storage cabinet,ultrasonic cleaning machine,endoscope cleaning center And other series of products and related supplies. https://www.facebook.com/zhanjie.wang.359 https://twitter.com/SanqiangMedical http://www.linkedin.com/company/13688847/admin/updates/ http://www.sterilizers-china.com/ wang@sterilizers-china.com 86- 13837222611 ZhanJie Wang
more

Send Inquiry

Your message must be between 20-3000 characters